3. For more help with RSS, visit http://www.montgomerycountymd.gov/apps/News/RSS/mcgRSS.asp--><channel><title>Gaithersburg Library Renovation</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?blogID=33</link><description>Construction updates</description><language>en-us</language><ttl>30</ttl><item><title>February 27-March 13, 2013</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2160</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2160</guid><description>&lt;p&gt;Henley Construction Company has reported that they have:&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Pepco set transformer and continues permanent power installation&lt;/li&gt; &lt;li&gt;Poured Stair #1&lt;/li&gt; &lt;li&gt;Continued spray fireproofing&lt;/li&gt; &lt;li&gt;Continued with air barrier, all areas&lt;/li&gt; &lt;li&gt;Continued fiber cement cladding&lt;/li&gt; &lt;li&gt;Started exterior standing seam wall panels&lt;/li&gt; &lt;li&gt;Continued with standing seam metal roof&lt;/li&gt; &lt;li&gt;Continued with curtain wall/storefront frame/glass installation&lt;/li&gt; &lt;li&gt;Completed stone veneer at retaining wall&lt;/li&gt; &lt;li&gt;Continued with interior/exterior stone veneer and split face cmu&lt;/li&gt; &lt;li&gt;Continued pluming rough in, all areas&lt;/li&gt; &lt;li&gt;Continued electric rough in, all areas&lt;/li&gt; &lt;li&gt;Continued duct work installation, all areas&lt;/li&gt; &lt;li&gt;Measured interior storefront frames/began fabrication&lt;/li&gt; &lt;li&gt;Continued sprinkler mains and branches, all areas&lt;/li&gt; &lt;li&gt;Started&amp;nbsp; hanging drywall first and second floors, north end&lt;/li&gt; &lt;li&gt;Started building elevator shaft on stair one walls&lt;/li&gt; &lt;li&gt;Continued roofing deficiency repairs, per Gale reports&lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by Kay Bowman&lt;/p&gt;</description><pubDate>14 Mar 2013 00:00:00 EST</pubDate></item><item><title>February 13-February 26, 2013</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2148</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2148</guid><description>&lt;p&gt;Henley Construction Company has reported that they have:&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Started upper level spray fire proofing &lt;/li&gt; &lt;li&gt;Continued with air barrier, all areas &lt;/li&gt; &lt;li&gt;Installation of fiber cement panel &lt;/li&gt; &lt;li&gt;Continued metal roof installation &lt;/li&gt; &lt;li&gt;Continued window installation &lt;/li&gt; &lt;li&gt;Continued interior stone veneer on exterior cmu &lt;/li&gt; &lt;li&gt;Continued pluming rough ins, all areas &lt;/li&gt; &lt;li&gt;Continued with electric rough ins, all areas &lt;/li&gt; &lt;li&gt;Continued with duct installation, south end &lt;/li&gt; &lt;li&gt;Started sprinkler mains and branches, 1st/2nd floors &lt;/li&gt; &lt;li&gt;Installed coiling door supports and doors, 1st/2nd floors &lt;/li&gt; &lt;li&gt;Installed switchgear &lt;/li&gt; &lt;li&gt;Connected storm lines from bldg to flow splitter 1 &lt;/li&gt; &lt;li&gt;Began fixing roof deficiencies per Gail Reports &lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by Kay Bowman&lt;/p&gt;</description><pubDate>26 Feb 2013 00:00:00 EST</pubDate></item><item><title>January 31, 2013-February 12, 2013</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2141</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2141</guid><description>&lt;p&gt;Henley Construction Company has reported that they have:&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Finished interior spray fire proofing 1st floor SW/SE &lt;/li&gt; &lt;li&gt;Continued with air barrier &lt;/li&gt; &lt;li&gt;Continued with fiber cement system mock-up &lt;/li&gt; &lt;li&gt;Started exterior windows and curtain wall first floor &lt;/li&gt; &lt;li&gt;Finished low roof installation at green roof/canopies with exception of deficiency items &lt;/li&gt; &lt;li&gt;Continued electric rough-ins all areas &lt;/li&gt; &lt;li&gt;Started ductwork mains south west side &lt;/li&gt; &lt;li&gt;Continued with plumbing rough-in all areas &lt;/li&gt; &lt;li&gt;Started sprinkler rough-in at basement &lt;/li&gt; &lt;li&gt;Continued interior wall framing &lt;/li&gt; &lt;li&gt;Continued with stone veneer &lt;/li&gt; &lt;li&gt;Continued electric rough-ins 2nd and 3rd floors &lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by Kay Bowman&lt;/p&gt;</description><pubDate>19 Feb 2013 00:00:00 EST</pubDate></item><item><title>January 17 to January 30, 2013</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2129</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2129</guid><description>&lt;p&gt;Henley Construction Company has reported that they have: &lt;/p&gt; &lt;ul&gt; &lt;li&gt;Finished low roof fireproofing 1st floor SW/SE; &lt;/li&gt; &lt;li&gt;Finished fiber cement panel mock up; &lt;/li&gt; &lt;li&gt;Started exterior window installation; &lt;/li&gt; &lt;li&gt;Finished low roof installation except some flashings around other trades; &lt;/li&gt; &lt;li&gt;Continued elect rough-in all areas; &lt;/li&gt; &lt;li&gt;Started duct work, 1st floor SW; &lt;/li&gt; &lt;li&gt;started sprinkler rough-in at basement Interior wall framing; &lt;/li&gt; &lt;li&gt;Continued interior stone veneer; and&amp;nbsp; &lt;/li&gt; &lt;li&gt;Continued electric rough-ins, 2nd and 3rd floors &lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by Kay Bowman&lt;/p&gt; &lt;p&gt;&amp;nbsp;&lt;/p&gt; &lt;p&gt;&amp;nbsp;&lt;/p&gt;</description><pubDate>30 Jan 2013 00:00:00 EST</pubDate></item><item><title>January 3, 2013 to January 16, 2013</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2124</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2124</guid><description>&lt;p&gt;Henley Construction Company reports that they have&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Installed steel framing enclosure, chiller area&amp;nbsp;&lt;/li&gt; &lt;li&gt;Completed&amp;nbsp;interior spray fireproofing 1st Floor SW&lt;/li&gt; &lt;li&gt;Started 1st floor SE spray fireproofing&lt;/li&gt; &lt;li&gt;Continued installing air barrier; &lt;/li&gt; &lt;li&gt;Continued interior wall framing; &lt;/li&gt; &lt;li&gt;Started mock up for fiber cement panels&lt;/li&gt; &lt;li&gt;Started window flashings&lt;/li&gt; &lt;li&gt;Continued with low roof installation&lt;/li&gt; &lt;li&gt;Continued with electric panel equipment main electric room&lt;/li&gt; &lt;li&gt;Continued testing and installing ducts &lt;/li&gt; &lt;li&gt;Continued mechanical and plumbing rough-in all areas&lt;/li&gt; &lt;li&gt;Started stone veneer, and&amp;nbsp;&lt;/li&gt; &lt;li&gt;Started&amp;nbsp; electric rough-ins on second floor.&lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by K. Bowman&lt;/p&gt;</description><pubDate>16 Jan 2013 00:00:00 EST</pubDate></item><item><title>December 22, 2012 to January 2, 2013</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2115</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2115</guid><description>&lt;p&gt;Henley Construction Company reports that they have&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Begun low roof insulation; &lt;/li&gt; &lt;li&gt;Started interior spray fireproofing on the first foor; &lt;/li&gt; &lt;li&gt;Set the skylight; &lt;/li&gt; &lt;li&gt;Continued installing air barrier; &lt;/li&gt; &lt;li&gt;Continued interior wall framing; &lt;/li&gt; &lt;li&gt;Continued installing ducts in north end on all levels; &lt;/li&gt; &lt;li&gt;Scheduled duct testing; &lt;/li&gt; &lt;li&gt;Begun sanitary wall rough-ins; &lt;/li&gt; &lt;li&gt;Continued electrical rough-ins on north end;&amp;nbsp;and &lt;/li&gt; &lt;li&gt;Started temporary heating of the building. &lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by R. Gale&lt;/p&gt;</description><pubDate>08 Jan 2013 00:00:00 EST</pubDate></item><item><title>December 5-December 22, 2012</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2114</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2114</guid><description>&lt;p&gt;Henley Construction Company reports that they have&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Prepared for installation of metal at high roof/monitor roof;&amp;nbsp; &lt;/li&gt; &lt;li&gt;Contiued installing PVC low roof; &lt;/li&gt; &lt;li&gt;Begun installation of air barrier; &lt;/li&gt; &lt;li&gt;Continued duct work installation at North end of library; &lt;/li&gt; &lt;li&gt;Continued interior light gauge framing; &lt;/li&gt; &lt;li&gt;Continued plumbing and electrical rough-in for all areas; &lt;/li&gt; &lt;li&gt;Completed stone veneer sample panel; &lt;/li&gt; &lt;li&gt;Installed steel at chimney infill; &lt;/li&gt; &lt;li&gt;Started mechanical, piping in basement and chill water piping; &lt;/li&gt; &lt;li&gt;Started installing&amp;nbsp;duct branches on second floor; &lt;/li&gt; &lt;li&gt;Continued installing duct branches on first floor north; &lt;/li&gt; &lt;li&gt;Started setting door frames on north end;&amp;nbsp;and &lt;/li&gt; &lt;li&gt;Tied in storm water lines from roof dreains in all areas. &lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by R. Gale&lt;/p&gt;</description><pubDate>08 Jan 2013 00:00:00 EST</pubDate></item><item><title>November 21-December 5, 2012</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2113</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2113</guid><description>&lt;p&gt;Henley Construction Company reports that they have&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Completed field measurements for exterior fiber cement panels; &lt;/li&gt; &lt;li&gt;Set emergency generator; &lt;/li&gt; &lt;li&gt;Continued working on exterior framing and sheathing; &lt;/li&gt; &lt;li&gt;Started&amp;nbsp;PVC low roof installation; &lt;/li&gt; &lt;li&gt;Finished roof blocking; &lt;/li&gt; &lt;li&gt;Finished form rolling sheet metal for high roof installation; &lt;/li&gt; &lt;li&gt;Hung VAV units at 1st/2nd floor North; &lt;/li&gt; &lt;li&gt;Worked on duct main/branches at 1st and 2nd floor North; &lt;/li&gt; &lt;li&gt;Continued interior light gauge framing; &lt;/li&gt; &lt;li&gt;Continued plumbing and electrical rough-in for all areas; &lt;/li&gt; &lt;li&gt;Started window fabrication; and &lt;/li&gt; &lt;li&gt;Finished substrate for&amp;nbsp;light monitor roof. &lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by R. Gale&lt;/p&gt;</description><pubDate>08 Jan 2013 00:00:00 EST</pubDate></item><item><title>November 7-November 21, 2012</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2112</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2112</guid><description>&lt;p&gt;Henley Construction Company reports that they have&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Delivered and set the chiller;&lt;/li&gt; &lt;li&gt;Continued with interior light gauge framing;&lt;/li&gt; &lt;li&gt;Finished stair 1 installation;&lt;/li&gt; &lt;li&gt;Began fabricating high roof panels;&lt;/li&gt; &lt;li&gt;Started low roof installation;&lt;/li&gt; &lt;li&gt;Finished roof blocking;&lt;/li&gt; &lt;li&gt;Continued electrical and&amp;nbsp;plumbing rough-ins;&lt;/li&gt; &lt;li&gt;Finished interior CMU walls in basement area;&lt;/li&gt; &lt;li&gt;Started field measuring for windows; and &lt;/li&gt; &lt;li&gt;Started light monitor roof.&amp;nbsp;&lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by R. Gale&lt;/p&gt;</description><pubDate>08 Jan 2013 00:00:00 EST</pubDate></item><item><title>October 24 to November 7, 2012</title><link>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2084</link><guid>
				http://www.montgomerycountymd.gov/apps/News/Blog/LibraryBlog.asp?BlogID=33&amp;ItemBlogID=2084</guid><description>&lt;p&gt;Henley Construction Company reports that they have&lt;/p&gt; &lt;ul&gt; &lt;li&gt;Started interior metal framing;&lt;/li&gt; &lt;li&gt;Completed exterior metal framing&amp;nbsp;except at book drop;&lt;/li&gt; &lt;li&gt;Started installation of Stair No. 1;&amp;nbsp;&lt;/li&gt; &lt;li&gt;Started Installation of high roof;&lt;/li&gt; &lt;li&gt;Started setting air handling units at the mechanical level and in basement.;&lt;/li&gt; &lt;li&gt;Poured new electric room slab;&lt;/li&gt; &lt;li&gt;Poured chiller and generator pads;&lt;/li&gt; &lt;li&gt;Started setting boilers and pumps in basement;&lt;/li&gt; &lt;li&gt;Started hangers and duct in basement; and &lt;/li&gt; &lt;li&gt;Filled existing brick columns with concrete.&lt;/li&gt; &lt;/ul&gt; &lt;p&gt;Posted by R. Gale&lt;/p&gt;</description><pubDate>18 Nov 2012 00:00:00 EST</pubDate></item></channel></rss>