Choose the correct answer for each question by clicking on the appropriate letter (A,B,C,D). If you get an "X" then select again, until you get a ":-)" .
What should be the first course of action when you have a face piece failure?
Exit the building
Cover with a gloved hand
Open purge valve intermittently
Buddy breathing
What should be the first course of action when you suffer a regulator malfunction?
Finish your task in the building
Cover with a gloved hand
Open purge valve intermittenly
Buddy breathing
What is the initial course of action when you have a total air depletion situation?
Notify partner & exit the building
Cover with a gloved hand & exit the building
Open purge valve intermittently & exit the building
Buddy breathing & exit the building
After you have notifed your partner what is the next course of action when you have a pressure reducer malfunction?
Exit the building
Cover with a gloved hand
Open purge valve intermittently
Buddy breathing
On the Heads Up Display (HUD) what does the Red Round Indicator light mean?
Low battery warning
3/4 air supply remaining in the cylinder
1/2 air supply remaining in the cylinder
1/4 air supply remaining in the cylinder
How much air remains in the cylinder when the RED Square is rapidly flashing in the Heads Up Display (HUD)?
Full air supply
3/4 air supply remaining in the cylinder
1/2 air supply remaining in the cylinder
1/4 air supply remaining in the cylinder
How much air remains in the cylinder when the YELLOW SQUARE indicator is flashing slowly in the Heads Up Display (HUD)?
Full air supply in the cylinder
3/4 air supply remaining in the cylinder
1/2 air supply remaining in the cylinder
1/4 air supply remaining in the cylinder
Low battery warning
How much air remains in the cylinder when there is a single GREEN indicator light illuminated in the Heads Up Display (HUD)?
Full air supply in cylinder
3/4 air supply remaining in the cylinder
1/2 air supply remaining in the cylinder
1/4 ar supply remaining in the cylinder
Low battery warning
How much air remains in the cylinder when you have two Green indicator lights illuminated in the Heads Up Display (HUD)?
Full air supply in cylinder
3/4 air supply remianing in the cylinder
1/2 air supply remaining in the cylinder
1/4 air supply remaining in the cylinder
Low battery warning
What is the PSI of a full cylinder when properly filled?
4300 psi
5100 psi
4200 psi
4500 psi
Under normal operating conditions what cylinder pressure will the vibra alert activate?
1100 psi
1000 psi
500 psi
150 psi
At what pressure does air enter the regulator under normal conditions?
100 psi
114 psi
150 psi
20 psi
What pressure entering the regulator is required for the Vibra-alert to opreate?
14.7
300
150
500
What is NOT a common atmospheres associated with fires or other emergencies?
Enriched oxygen levels
Elevated temperatures
Smoke
Toxic Atmospheres
What fire related toxic gas is responsible for most fire related deaths?
Hydrogen Cyanide
Carbon Dioxide
Carbon Monoxide
Phosgene
To operate effectively, the firefighter must be aware of the limitations of protective breathing apparatus. Which is not a limitation?
Wearer
Air supply
Equipment
Weather
Give the proper position of the bypass (purge) valve on the Scott 4.5 positive-pressure SCBA under normal conditions.
Turned clockwise (right) all the way clockwise
Open halfway to allow air through
Turned counter clockwise (left) all the way
Pushed in towrd the regulator until it clicks
At what minimum pressure does MCFR policy state that the cylinders should be refilled?
4200 psi
4400 psi
4000 psi
4500 psi
Can you activate the emergency button on the Integrated PASS device without opening the air cylinder?
Yes, you can
Yes, but the cylinder can only be cracked open
No, it will not activate
Yes, only when the cylinder is below 4000 psi
What initial action should be taken to facilitate communication when a downed firefighter is located?
Use hand signals
Silence the PASS device
Resume normal radio communication
Advise command
Per Policy all SCBA on 1st line response units must be inspected?
Daily
Weekly
Daily and before and after use
Daily and after use
EBSS may only be used when both firefighters are__________________
mobile and ambulatory
unconscious and unresponsive
close and visible to exit
conscious and non-ambulatory
SCBA is required to use at what minimum PPM of CO?